MODEL
PRHR
Direct-acting, pressure reducing valve
SERIES 3 / CAPACITY: 160 L/min. / CAVITY: T-17A
Direct-acting, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced
pressure at port 1. These valves incorporate a damped construction for stable operation allowing the use of high
reduced pressure.
TECHNICAL DATA
Factory Pressure Settings Established at 30 cc/min.
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 65 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting 5
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-017-007
Seal kit - Cartridge Polyurethane: 990-017-002
Seal kit - Cartridge Viton: 990-017-006
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
K Handknob
(A)ADJUSTMENT RANGE
A 750 - 3000 psi (50 - 210 bar), 1000 psi
(70 bar) Standard Setting
B 300 - 1500 psi (20 - 105 bar), 500 psi (35
bar) Standard Setting
D 200 - 800 psi (14 - 55 bar), 400 psi (28
bar) Standard Setting
E 100 - 400 psi (7 - 28 bar), 200 psi (14
bar) Standard Setting
S 50 - 200 psi (3,5 - 14 bar), 100 psi (7 bar)
Standard Setting
W 1100 - 4500 psi (76 - 315 bar), 1100 psi
(76 bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/PRHR
TECHNICAL FEATURES
Note: This valve has no relieving capability. It should not be used in a dead-headed application. If the reduced pressure side of the circuit has very low leakage the
pressure may rise significantly. The pressure rise will vary from valve to valve.
This type of valve, PR*R, is a good replacement for an LP*C as a normally open, restrictive compensating element if a higher pressure drop across an orifice is
Model Code Example: PRHRLANCONFIGURATION OPTIONS